MicroFlowPLUS Kit
MicroFlowBASIC Kits (in vivo)

The Litron Advantage is delivered with every kit:
Faster Results Obtain results from scoring a complete Micronucleus Test in just one day. This is many times faster than the three to six weeks necessary for traditional microscopic methods.
More Data With the use of a flow cytometer, the MicroFlow process allows a researcher to score samples within a population of 20,000 reticulocytes, versus only 2,000 using traditional microscopic methods. This not only provides much tighter standard deviations, but also more objective data.
Greater Confidence MicroFlow data is accepted by the US FDA for the mouse micronucleus assay, a test required by regulatory agencies. Additionally, this method addresses all recommendations made by the International Workshop on Genotoxicity Test Procedures (IWGTP). Additionally, the most current Organization for Economic Co-Operation and Development (OECD) guidelines regarding micronucleus testing, Guideline 474, indicates that flow cytometry is an acceptable alternative to microscopic evaluation. Litron developed this patented process and routinely analyzes samples from MicroFlowBASIC kits, so you can feel confident using this proven method.

In Vivo MicroFlow kits contain all of the quality-assured supplies and reagents for you to collect and fix samples. Kits are available for use with a wide range of species, from mouse and rat up to human. Here's what you get, what it does and how your research is improved using MicroFlowBASIC Kits:
Feature Function Benefit
Solution A (fixative) Fixes blood cells prior to evaluation by flow cytometry. Cells can be maintained for months or years at -85 °C. This gives researchers the ability to accumulate samples over time, then analyze multiple time points at once.
Solution B (anticoagulant) Prevents blood cells from clotting before fixation. Allows samples to be fixed up to 6 hours after collection.
VWR 15ml conical
polypropylene tubes
Stores and protects fixed blood samples. These tubes are capable of being capped tightly to reduce diffusion of CO2 into samples. (Note: Other tubes have not been shown to perform adequately.)
Shipping container Keeps samples cold during shipping. This kit-supplied container is designed to ensure that fixed samples on dry ice will remain sufficiently cold for 48 to 72 hours.
Large plastic bags Protects fixed blood samples. Provides additional protection against CO2 diffusion into fixed samples during shipment.
 